Eaton offers a variety of UPS Monitoring Software that allows you to stay on top of your power needs. Download UPS Monitoring Software and Drivers. Fujitsu UPS devices ensure high-performance power supply protection for systems and data, and thus provide reliable protection against power failure, current fluctuations and electrical interference. Fujitsu offers both line interactive (VI) and online (VFI) devices with double conversion technology in line with the UPS.

WinPower is a powerful UPS monitoring software, which provides user-friendly interface to monitor and control your Inverter system. The software provides complete power protection for computer system while encountering power failure. With this software, users can monitor any UPS status on the same LAN. Furthermore, any UPS can protect any PC on the same LAN.

The WinPower V5.6.0.5 is released:
Date: 2018/12/29

1. Support ESXi 6.7

2. Support Mac 10.14

3. Support device renaming function

Ups

4. Support remote shutdown via SSH for Linux/Unix/NAS

Masterguard

5. Support a safely turn-off for all guest OS and ESXi host by any guest OS

6. New feature of UPS wizard, a UPS wizard pops out automatically at Winpower initial

---------------------------------------------------------------------------------

The WinPower V5.5.0.0 is released:
Date: 2018/5/25

1. Fix bug: Adding hostname or IP address of remote agent available under the WAN

2. Fix bug: Change password available via remote operation Hyperspin system wheel art.

Masterguard Ups Software Download For Pc

---------------------------------------------------------------------------------

Masterguard Ups Software Download Free


This is the MIB module UPS-MIB from Standards / RFCs. This OID tree represents the compiled SNMP MIB module UPS-MIB and includes only high-level compiled information. For more detail (mib object descriptions, Unit Types, Textual Conventions, Macro-definitions, etc.), please download the raw SNMP ASN.1 mib test file by clicking on the ZIP icon above. To query a live agent with SNMP for objects in module UPS-MIB, use OidView Network Management Tools or SNMP MIB Browser. To capture and analyze snmp traps from a live agent with objects loaded from module UPS-MIB, use OidView Trap Manager SNMP Fault Management

Statistics for MIB UPS-MIB:
Objects: 155OIDS: 148Object Groups: 25
Traps: 0Notifications: 4Notification Groups: 0
Tables: 4Tabulars: 17Scalars/Other: 98
Object NameObject IdentifierObject Type
upsMIB1.3.6.1.2.1.33MODULE-IDENTITY
upsObjects1.3.6.1.2.1.33.1OBJECT IDENTIFIER
upsIdent1.3.6.1.2.1.33.1.1OBJECT IDENTIFIER
upsIdentManufacturer1.3.6.1.2.1.33.1.1.1OBJECT-TYPE
upsIdentModel1.3.6.1.2.1.33.1.1.2OBJECT-TYPE
upsIdentUPSSoftwareVersion1.3.6.1.2.1.33.1.1.3OBJECT-TYPE
upsIdentAgentSoftwareVersion1.3.6.1.2.1.33.1.1.4OBJECT-TYPE
upsIdentName1.3.6.1.2.1.33.1.1.5OBJECT-TYPE
upsIdentAttachedDevices1.3.6.1.2.1.33.1.1.6OBJECT-TYPE
upsBattery1.3.6.1.2.1.33.1.2OBJECT IDENTIFIER
upsBatteryStatus1.3.6.1.2.1.33.1.2.1OBJECT-TYPE
upsSecondsOnBattery1.3.6.1.2.1.33.1.2.2OBJECT-TYPE
upsEstimatedMinutesRemaining1.3.6.1.2.1.33.1.2.3OBJECT-TYPE
upsEstimatedChargeRemaining1.3.6.1.2.1.33.1.2.4OBJECT-TYPE
upsBatteryVoltage1.3.6.1.2.1.33.1.2.5OBJECT-TYPE
upsBatteryCurrent1.3.6.1.2.1.33.1.2.6OBJECT-TYPE
upsBatteryTemperature1.3.6.1.2.1.33.1.2.7OBJECT-TYPE
upsInput1.3.6.1.2.1.33.1.3OBJECT IDENTIFIER
upsInputLineBads1.3.6.1.2.1.33.1.3.1OBJECT-TYPE
upsInputNumLines1.3.6.1.2.1.33.1.3.2OBJECT-TYPE
upsInputTable1.3.6.1.2.1.33.1.3.3OBJECT-TYPE
upsInputEntry1.3.6.1.2.1.33.1.3.3.1OBJECT-TYPE
upsInputLineIndex1.3.6.1.2.1.33.1.3.3.1.1OBJECT-TYPE
upsInputFrequency1.3.6.1.2.1.33.1.3.3.1.2OBJECT-TYPE
upsInputVoltage1.3.6.1.2.1.33.1.3.3.1.3OBJECT-TYPE
upsInputCurrent1.3.6.1.2.1.33.1.3.3.1.4OBJECT-TYPE
upsInputTruePower1.3.6.1.2.1.33.1.3.3.1.5OBJECT-TYPE
upsOutput1.3.6.1.2.1.33.1.4OBJECT IDENTIFIER
upsOutputSource1.3.6.1.2.1.33.1.4.1OBJECT-TYPE
upsOutputFrequency1.3.6.1.2.1.33.1.4.2OBJECT-TYPE
upsOutputNumLines1.3.6.1.2.1.33.1.4.3OBJECT-TYPE
upsOutputTable1.3.6.1.2.1.33.1.4.4OBJECT-TYPE
upsOutputEntry1.3.6.1.2.1.33.1.4.4.1OBJECT-TYPE
upsOutputLineIndex1.3.6.1.2.1.33.1.4.4.1.1OBJECT-TYPE
upsOutputVoltage1.3.6.1.2.1.33.1.4.4.1.2OBJECT-TYPE
upsOutputCurrent1.3.6.1.2.1.33.1.4.4.1.3OBJECT-TYPE
upsOutputPower1.3.6.1.2.1.33.1.4.4.1.4OBJECT-TYPE
upsOutputPercentLoad1.3.6.1.2.1.33.1.4.4.1.5OBJECT-TYPE
upsBypass1.3.6.1.2.1.33.1.5OBJECT IDENTIFIER
upsBypassFrequency1.3.6.1.2.1.33.1.5.1OBJECT-TYPE
upsBypassNumLines1.3.6.1.2.1.33.1.5.2OBJECT-TYPE
upsBypassTable1.3.6.1.2.1.33.1.5.3OBJECT-TYPE
upsBypassEntry1.3.6.1.2.1.33.1.5.3.1OBJECT-TYPE
upsBypassLineIndex1.3.6.1.2.1.33.1.5.3.1.1OBJECT-TYPE
upsBypassVoltage1.3.6.1.2.1.33.1.5.3.1.2OBJECT-TYPE
upsBypassCurrent1.3.6.1.2.1.33.1.5.3.1.3OBJECT-TYPE
upsBypassPower1.3.6.1.2.1.33.1.5.3.1.4OBJECT-TYPE
upsAlarm1.3.6.1.2.1.33.1.6OBJECT IDENTIFIER
upsAlarmsPresent1.3.6.1.2.1.33.1.6.1OBJECT-TYPE
upsAlarmTable1.3.6.1.2.1.33.1.6.2OBJECT-TYPE
upsAlarmEntry1.3.6.1.2.1.33.1.6.2.1OBJECT-TYPE
upsAlarmId1.3.6.1.2.1.33.1.6.2.1.1OBJECT-TYPE
upsAlarmDescr1.3.6.1.2.1.33.1.6.2.1.2OBJECT-TYPE
upsAlarmTime1.3.6.1.2.1.33.1.6.2.1.3OBJECT-TYPE
upsWellKnownAlarms1.3.6.1.2.1.33.1.6.3OBJECT IDENTIFIER
upsAlarmBatteryBad1.3.6.1.2.1.33.1.6.3.1OBJECT-IDENTITY
upsAlarmBypassBad1.3.6.1.2.1.33.1.6.3.10OBJECT-IDENTITY
upsAlarmOutputOffAsRequested1.3.6.1.2.1.33.1.6.3.11OBJECT-IDENTITY
upsAlarmUpsOffAsRequested1.3.6.1.2.1.33.1.6.3.12OBJECT-IDENTITY
upsAlarmChargerFailed1.3.6.1.2.1.33.1.6.3.13OBJECT-IDENTITY
upsAlarmUpsOutputOff1.3.6.1.2.1.33.1.6.3.14OBJECT-IDENTITY
upsAlarmUpsSystemOff1.3.6.1.2.1.33.1.6.3.15OBJECT-IDENTITY
upsAlarmFanFailure1.3.6.1.2.1.33.1.6.3.16OBJECT-IDENTITY
upsAlarmFuseFailure1.3.6.1.2.1.33.1.6.3.17OBJECT-IDENTITY
upsAlarmGeneralFault1.3.6.1.2.1.33.1.6.3.18OBJECT-IDENTITY
upsAlarmDiagnosticTestFailed1.3.6.1.2.1.33.1.6.3.19OBJECT-IDENTITY
upsAlarmOnBattery1.3.6.1.2.1.33.1.6.3.2OBJECT-IDENTITY
upsAlarmCommunicationsLost1.3.6.1.2.1.33.1.6.3.20OBJECT-IDENTITY
upsAlarmAwaitingPower1.3.6.1.2.1.33.1.6.3.21OBJECT-IDENTITY
upsAlarmShutdownPending1.3.6.1.2.1.33.1.6.3.22OBJECT-IDENTITY
upsAlarmShutdownImminent1.3.6.1.2.1.33.1.6.3.23OBJECT-IDENTITY
upsAlarmTestInProgress1.3.6.1.2.1.33.1.6.3.24OBJECT-IDENTITY
upsAlarmLowBattery1.3.6.1.2.1.33.1.6.3.3OBJECT-IDENTITY
upsAlarmDepletedBattery1.3.6.1.2.1.33.1.6.3.4OBJECT-IDENTITY
upsAlarmTempBad1.3.6.1.2.1.33.1.6.3.5OBJECT-IDENTITY
upsAlarmInputBad1.3.6.1.2.1.33.1.6.3.6OBJECT-IDENTITY
upsAlarmOutputBad1.3.6.1.2.1.33.1.6.3.7OBJECT-IDENTITY
upsAlarmOutputOverload1.3.6.1.2.1.33.1.6.3.8OBJECT-IDENTITY
upsAlarmOnBypass1.3.6.1.2.1.33.1.6.3.9OBJECT-IDENTITY
upsTest1.3.6.1.2.1.33.1.7OBJECT IDENTIFIER
upsTestId1.3.6.1.2.1.33.1.7.1OBJECT-TYPE
upsTestSpinLock1.3.6.1.2.1.33.1.7.2OBJECT-TYPE
upsTestResultsSummary1.3.6.1.2.1.33.1.7.3OBJECT-TYPE
upsTestResultsDetail1.3.6.1.2.1.33.1.7.4OBJECT-TYPE
upsTestStartTime1.3.6.1.2.1.33.1.7.5OBJECT-TYPE
upsTestElapsedTime1.3.6.1.2.1.33.1.7.6OBJECT-TYPE
upsWellKnownTests1.3.6.1.2.1.33.1.7.7OBJECT IDENTIFIER
upsTestNoTestsInitiated1.3.6.1.2.1.33.1.7.7.1OBJECT-IDENTITY
upsTestAbortTestInProgress1.3.6.1.2.1.33.1.7.7.2OBJECT-IDENTITY
upsTestGeneralSystemsTest1.3.6.1.2.1.33.1.7.7.3OBJECT-IDENTITY
upsTestQuickBatteryTest1.3.6.1.2.1.33.1.7.7.4OBJECT-IDENTITY
upsTestDeepBatteryCalibration1.3.6.1.2.1.33.1.7.7.5OBJECT-IDENTITY
upsControl1.3.6.1.2.1.33.1.8OBJECT IDENTIFIER
upsShutdownType1.3.6.1.2.1.33.1.8.1OBJECT-TYPE
upsShutdownAfterDelay1.3.6.1.2.1.33.1.8.2OBJECT-TYPE
upsStartupAfterDelay1.3.6.1.2.1.33.1.8.3OBJECT-TYPE
upsRebootWithDuration1.3.6.1.2.1.33.1.8.4OBJECT-TYPE
upsAutoRestart1.3.6.1.2.1.33.1.8.5OBJECT-TYPE
upsConfig1.3.6.1.2.1.33.1.9OBJECT IDENTIFIER
upsConfigInputVoltage1.3.6.1.2.1.33.1.9.1OBJECT-TYPE
upsConfigHighVoltageTransferPoint1.3.6.1.2.1.33.1.9.10OBJECT-TYPE
upsConfigInputFreq1.3.6.1.2.1.33.1.9.2OBJECT-TYPE
upsConfigOutputVoltage1.3.6.1.2.1.33.1.9.3OBJECT-TYPE
upsConfigOutputFreq1.3.6.1.2.1.33.1.9.4OBJECT-TYPE
upsConfigOutputVA1.3.6.1.2.1.33.1.9.5OBJECT-TYPE
upsConfigOutputPower1.3.6.1.2.1.33.1.9.6OBJECT-TYPE
upsConfigLowBattTime1.3.6.1.2.1.33.1.9.7OBJECT-TYPE
upsConfigAudibleStatus1.3.6.1.2.1.33.1.9.8OBJECT-TYPE
upsConfigLowVoltageTransferPoint1.3.6.1.2.1.33.1.9.9OBJECT-TYPE
upsTraps1.3.6.1.2.1.33.2OBJECT IDENTIFIER
upsTrapOnBattery1.3.6.1.2.1.33.2.1NOTIFICATION-TYPE
upsTrapTestCompleted1.3.6.1.2.1.33.2.2NOTIFICATION-TYPE
upsTrapAlarmEntryAdded1.3.6.1.2.1.33.2.3NOTIFICATION-TYPE
upsTrapAlarmEntryRemoved1.3.6.1.2.1.33.2.4NOTIFICATION-TYPE
upsConformance1.3.6.1.2.1.33.3OBJECT IDENTIFIER
upsCompliances1.3.6.1.2.1.33.3.1OBJECT IDENTIFIER
upsSubsetCompliance1.3.6.1.2.1.33.3.1.1MODULE-COMPLIANCE
upsBasicCompliance1.3.6.1.2.1.33.3.1.2MODULE-COMPLIANCE
upsFullCompliance1.3.6.1.2.1.33.3.1.3MODULE-COMPLIANCE
upsGroups1.3.6.1.2.1.33.3.2OBJECT IDENTIFIER
upsSubsetGroups1.3.6.1.2.1.33.3.2.1OBJECT IDENTIFIER
upsSubsetIdentGroup1.3.6.1.2.1.33.3.2.1.1OBJECT-GROUP
upsSubsetBatteryGroup1.3.6.1.2.1.33.3.2.1.2OBJECT-GROUP
upsSubsetInputGroup1.3.6.1.2.1.33.3.2.1.3OBJECT-GROUP
upsSubsetOutputGroup1.3.6.1.2.1.33.3.2.1.4OBJECT-GROUP
upsSubsetAlarmGroup1.3.6.1.2.1.33.3.2.1.6OBJECT-GROUP
upsSubsetControlGroup1.3.6.1.2.1.33.3.2.1.8OBJECT-GROUP
upsSubsetConfigGroup1.3.6.1.2.1.33.3.2.1.9OBJECT-GROUP
upsBasicGroups1.3.6.1.2.1.33.3.2.2OBJECT IDENTIFIER
upsBasicIdentGroup1.3.6.1.2.1.33.3.2.2.1OBJECT-GROUP
upsBasicBatteryGroup1.3.6.1.2.1.33.3.2.2.2OBJECT-GROUP
upsBasicInputGroup1.3.6.1.2.1.33.3.2.2.3OBJECT-GROUP
upsBasicOutputGroup1.3.6.1.2.1.33.3.2.2.4OBJECT-GROUP
upsBasicBypassGroup1.3.6.1.2.1.33.3.2.2.5OBJECT-GROUP
upsBasicAlarmGroup1.3.6.1.2.1.33.3.2.2.6OBJECT-GROUP
upsBasicTestGroup1.3.6.1.2.1.33.3.2.2.7OBJECT-GROUP
upsBasicControlGroup1.3.6.1.2.1.33.3.2.2.8OBJECT-GROUP
upsBasicConfigGroup1.3.6.1.2.1.33.3.2.2.9OBJECT-GROUP
upsFullGroups1.3.6.1.2.1.33.3.2.3OBJECT IDENTIFIER
upsFullIdentGroup1.3.6.1.2.1.33.3.2.3.1OBJECT-GROUP
upsFullBatteryGroup1.3.6.1.2.1.33.3.2.3.2OBJECT-GROUP
upsFullInputGroup1.3.6.1.2.1.33.3.2.3.3OBJECT-GROUP
upsFullOutputGroup1.3.6.1.2.1.33.3.2.3.4OBJECT-GROUP
upsFullBypassGroup1.3.6.1.2.1.33.3.2.3.5OBJECT-GROUP
upsFullAlarmGroup1.3.6.1.2.1.33.3.2.3.6OBJECT-GROUP
upsFullTestGroup1.3.6.1.2.1.33.3.2.3.7OBJECT-GROUP
upsFullControlGroup1.3.6.1.2.1.33.3.2.3.8OBJECT-GROUP
upsFullConfigGroup1.3.6.1.2.1.33.3.2.3.9OBJECT-GROUP

This file automagically generated by OidView Network and Fault Management Tools and SNMP MIB Browser.